The R2G Power Relay is a high quality and durable product that is perfect for a variety of industrial and commercial applications. This relay is available in 1 or 2 poles and features a high capacity design that makes it perfect for powering large loads. The R2G Power Relay also features a high sensitive of consumed power, ensuring that it can handle even the most demanding loads without issue. Additionally, the relay features up to 8mm.
Request A QuoteR2G power relay consists of a relay and socket. The control voltage range can be extended using a matching socket. It can be used with the following types of sockets: SRC05-ST RG2 socket, SRC08-ST RG2 socket, SRC05-E RG2 socket, SRC08-E RG2 socket, and SRB05-E RG2 socket.
Automotive micro relay appliance
Our workshops have clean control, dust free, constant temperature and humidity. Everyone should on the anti-static clothes when enter workshop.
Contact | Configuration | 1C/1A | 2C/2A | |
Load | Resistive load (AC-1) | 12A,16A/250VAC,30VDC | 8A/250VAC,30VDC | |
Motor load (AC-15) | 1/2HP, 240VAC;3/4HP,120VAC | 1/3HP,240VAC,1/4HP,120VAC | ||
Max. switching capacity (resistive) | 3000VA,360W;4000VA,480W | 2000VA,240W | ||
Min. switching capacity | 170mW(17V/10mA) | |||
Initial contact resistance | ≤100mΩ | |||
Material | Ag alloy | |||
Electric durability (110% rated voltage , 85℃) | 3.5mm: 1NO 12A; 1NC 6A ≥105 Cycles(85ºC | 5.0mm: 2NO 8A; 2NC 4A ≥105Cycles(85ºC) | ||
5.0mm: 1NO 16A; 1NC 8A ≥10 Cycles(85ºC) | – | |||
Durability (Normal temperature | 3.5mm: 1NO 12A; 1NC 12A ≥5x104Cycles (23ºC) | 5.0mm: 2NO 8A; 2NC 8A ≥5×10 Cycles(23ºC) | ||
5.0mm: 1NO 16A; 1NC 16A ≥3×10 Cycles(23ºC) | – | |||
Mechanical durability | Dc≥5000×104 Cycles (18000 Ops/h); Ac≥3000×104 Cycles (18000 Ops/h) | |||
Pick-up voltage (23℃) (Rated voltage) | DC≤70% | |||
Drop-out voltage (23℃) (Rated voltage) | DC:≥10% | |||
Maximum voltage (23℃) (Rated voltage) | 130% | |||
Insulation resistance | ≥1000MΩ (500VDC) | |||
Coil operating power | DC(W) | approx. 0.43 | ||
AC(VA) | approx. 1 | |||
Operate time | ≤10ms | |||
Release time (at nominal voltage) | ≤5ms | |||
Initial breakdown voltage | Between open contacts | 1000VAC/1min (leakage current 1mA) | 1000VAC/1min (leakage current 1mA) | |
Between poles | 2500VAC/1min (leakage current 1mA | |||
Between contacts and coil | 5000VAC/1min (leakage current 1mA) | 5000VAC/1min (leakage current 1mA) | ||
Insulation characteristics IEC 60664 UL840 | Rated voltage | 250VAC | ||
Pollution level | 3 | |||
Overvoltage level | III | |||
Protection level | IP50 | |||
Storage temperature/ humbidity | -55~+85℃/ ≤85%RH (18 months) | |||
Working temperature/ humbidity | -40~+85℃/ 5%~85%RH (No condensation) | |||
Air pressure | 86~106KPa | |||
Shock resistance | 10G (half-sine shock pulse: 11ms) | |||
Vibration resistance | 10~55Hz double-amplitude:1.5mm | |||
Mounting | PCB | |||
Unit weight | approx. 13g |
Nominal voltage V.DC | 5 | 6 | 9 | 12 | 24 | 48 | 60 | 110 |
Coil resistance Ω | 62.5 | 90 | 200 | 360 | 1440 | 5220 | 8570 | 28800 |
Nominal voltage V.AC | 24 | 115 | 230 | / | / | / | / | / |
Coil resistance Ω | 350 | 8100 | 23800 | / | / | / | / | / |
Remark: Coil resistance under coil voltage 110V is measured with a tolerance of ±10%Ω, above coil voltage, 110V is measured with a tolerance of ±15%Ω. |